Siemens Desigo CC family
A Client Code Execution (CCE) vulnerability has been identified in Desigo CC, potentially allowing malicious actors to execute arbitrary code on client devices through specially crafted graphics documents. This vulner...
Active vulnerabilities, advisories, and threat intelligence — filtered for IT practitioners.
A Client Code Execution (CCE) vulnerability has been identified in Desigo CC, potentially allowing malicious actors to execute arbitrary code on client devices through specially crafted graphics documents. This vulner...
SIMOVE Fleetmanager and SIPLANT contain a path traversal vulnerability that could allow an attacker to access files outside of intended scope. Siemens has released new versions for the affected products and recommends...
A vulnerability has been identified in the Open Interface Services (OIS) web module affecting Siveillance Control and Siveillance Control Pro (versions OIS 3.x.y and OIS 4.x.y) . This vulnerability allows an attacker...
Successful exploitation of this vulnerability could allow an attacker to gain full code execution on the device. The following versions of lwIP TCP/IP Stack MQTT Client Application are affected: MQTT Client Applicatio...
Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in...
ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026...
Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity...
Successful exploitation of these vulnerabilities could allow unauthorized access to telemetry data and firmware. The following versions of Bransys ELD are affected: Android <11.00.00 (CVE-2026-86520, CVE-2026-86689, C...
Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPR...
Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communi...
A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting...
Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recomm...
Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client. The following...
Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recove...
Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash o...
Successful exploitation of these vulnerabilities could allow an attacker to exfiltrate date or cause a denial-of-service condition. The following versions of NextGen Healthcare Mirth Connect are affected: Mirth Connec...
Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session. The following versions of AVEVA Pipeline Integrity Moni...
Successful exploitation of this vulnerability could allow an attacker to take full control of the device. The following versions of CareCam Pro IP Cameras are affected: ANJIA AJL33PC0801 Firmware linux_linux_202008261...
Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/*...
Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor...