Summary
Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version.The following versions of Siemens Mendix SAML are affected:
- Mendix SAML (Mendix 10 compatible) vers:intdot/<4.2.3 (CVE-2026-80465)
- Mendix SAML (Mendix 11 compatible) vers:intdot/<4.2.3 (CVE-2026-80465)
- Mendix SAML (Mendix 9.24 compatible) vers:intdot/<3.6.27 (CVE-2026-80465)
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.7
Siemens
Siemens Mendix SAML
Improper Verification of Cryptographic Signature
Background
- Critical Infrastructure Sectors: Critical Manufacturing, Information Technology
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-80465
Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations.
View CVE Details
Affected Products
Siemens Mendix SAML
Vendor:Siemens
Product Version:Mendix SAML (Mendix 10 compatible) < V4.2.3, Mendix SAML (Mendix 11 compatible) < V4.2.3, Mendix SAML (Mendix 9.24 compatible) < V3.6.27
Product Status:known_affected
Remediations
Vendor fixUpdate to V3.6.27 or later version
https://marketplace.mendix.com/link/component/1174
Vendor fixUpdate to V4.2.3 or later version
https://marketplace.mendix.com/link/component/1174
Vendor fixUpdate to V4.2.3 or later version
https://marketplace.mendix.com/link/component/1174
Relevant CWE: CWE-347 Improper Verification of Cryptographic SignatureMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
8.7
HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N
Acknowledgments
- Siemens ProductCERT reported this vulnerability to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security, and following the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
For more information see the associated Siemens security advisory SSA-887643 in HTML and CSAF.
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
- Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolate them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-887643 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
- Initial Release Date: 2026-09-03
Date
Revision
Summary
2026-09-03
1
Publication Date
2026-09-15
2
Initial CISA Republication of Siemens ProductCERT SSA-887643 advisory