Summary
Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recover stored credentials.The following versions of CareCam CM2507 are affected:
- HMT.CM2507 Firmware v251211.1507 (CVE-2026-88259, CVE-2026-84398, CVE-2026-84400, CVE-2026-81305, CVE-2026-85478, CVE-2026-85497, CVE-2026-81321)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.5
CareCam
CareCam CM2507
Missing Authentication for Critical Function, Empty Password in Configuration File, Inclusion of Functionality from Untrusted Control Sphere, Use of Password Hash With Insufficient Computational Effort, Cleartext Storage of Sensitive Information
Background
- Critical Infrastructure Sectors: Commercial Facilities
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: China
Vulnerabilities
Expand All +
CVE-2026-88259
CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-306 Missing Authentication for Critical FunctionMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
4.0
8.7
HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CVE-2026-84398
CM2507 IP cameras accept an empty password for a privileged account exposed through its ONVIF management service. An attacker with network access to the affected device could access privileged management functions and obtain device, user, media-profile, and stream configuration information.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-258 Empty Password in Configuration FileMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
4.0
8.7
HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CVE-2026-84400
CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-306 Missing Authentication for Critical FunctionMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
3.1
LOW
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
4.0
2.3
LOW
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
CVE-2026-81305
CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-829 Inclusion of Functionality from Untrusted Control SphereMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
6.8
MEDIUM
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0
7
HIGH
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVE-2026-85478
A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access functionality that permits inspection or modification of boot configuration, firmware data, and software loaded by the device.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-306 Missing Authentication for Critical FunctionMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
3.5
LOW
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
4.0
2.4
LOW
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
CVE-2026-85497
CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational EffortMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0
9.3
CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVE-2026-81321
CM2507 IP cameras store configured wireless network credentials in cleartext within the device filesystem. An attacker who obtains filesystem access through physical access, a debugging interface, or another vulnerability could recover the configured network identifier and pre-shared key.
View CVE Details
Affected Products
CareCam CM2507
Vendor:CareCam
Product Version:CareCam HMT.CM2507 Firmware: v251211.1507
Product Status:known_affected
Remediations
MitigationCareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
Relevant CWE: CWE-312 Cleartext Storage of Sensitive InformationMetrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0
9.3
CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Acknowledgments
- Ben Law reported these vulnerabilities to CISA.
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
Revision History
- Initial Release Date: 2026-09-15
Date
Revision
Summary
2026-09-15
1
Initial Publication