View CSAF

Summary

A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions.

The following versions of Siemens Teamcenter are affected:

  • Teamcenter V2412 vers:intdot/<2412.0013 (CVE-2026-58113)
  • Teamcenter V2506 vers:intdot/<2506.0010 (CVE-2026-58113)
  • Teamcenter V2512 vers:intdot/<2512.2607 (CVE-2026-58113)
  • Teamcenter V2606 vers:intdot/<2606.2607 (CVE-2026-58113)

CVSS

Vendor

Equipment

Vulnerabilities

v3 6.1

Siemens

Siemens Teamcenter

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Background

  • Critical Infrastructure Sectors: Critical Manufacturing, Information Technology
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Germany

Vulnerabilities

Expand All +

CVE-2026-58113

Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.

View CVE Details

Affected Products

Siemens Teamcenter

Vendor:

Siemens

Product Version:

Teamcenter V2412 < V2412.0013, Teamcenter V2506 < V2506.0010, Teamcenter V2512 < V2512.2607, Teamcenter V2606 < V2606.2607

Product Status:

known_affected

Remediations

Vendor fix

Update to V2412.0013 or later version

https://support.sw.siemens.com/product/282219420/

Vendor fix

Update to V2506.0010 or later version

https://support.sw.siemens.com/product/282219420/

Vendor fix

Update to V2512.2607 or later version

https://support.sw.siemens.com/product/282219420/

Vendor fix

Update to V2606.2607 or later version

https://support.sw.siemens.com/product/282219420/

Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Metrics

CVSS Version

Base Score

Base Severity

Vector String

3.1

6.1

MEDIUM

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Acknowledgments

  • Enzo Alvarez from Bishop Fox reported this vulnerability to Siemens.

General Recommendations

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Additional Resources

For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-157465 in HTML and CSAF.

Terms of Use

The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).

Recommended Practices

CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.

  • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolate them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

Advisory Conversion Disclaimer

This ICSA is a verbatim republication of Siemens ProductCERT SSA-157465 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.

Revision History

  • Initial Release Date: 2026-09-08

Date

Revision

Summary

2026-09-08

1

Publication Date

2026-09-15

2

Initial CISA Republication of Siemens ProductCERT SSA-157465 advisory