Summary
The following versions of Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix are affected:
- ControlLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)
- GuardLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)
- CompactLogix 5380 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)
- Compact GuardLogix 5380 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)
- CompactLogix 5480 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.5
Rockwell Automation
Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix
Loop with Unreachable Exit Condition ('Infinite Loop')
Background
- Critical Infrastructure Sectors: Critical Manufacturing
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2021-42260
A potential denial of service vulnerability exists in the affected products and can be triggered via corrupt crafted data. This could result in a major nonrecoverable fault (MNRF). A program download is required to recover safety controllers. For non-safety controllers, a stage 2 reset is required to recover.
View CVE Details
Affected Products
Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix
Vendor:Rockwell Automation
Product Version:Rockwell Automation ControlLogix 5580 <34.015, Rockwell Automation ControlLogix 5580 <35.014, Rockwell Automation ControlLogix 5580 <36.013, Rockwell Automation ControlLogix 5580 <37.011, Rockwell Automation GuardLogix 5580 <34.015, Rockwell Automation GuardLogix 5580 <35.014, Rockwell Automation GuardLogix 5580 <36.013, Rockwell Automation GuardLogix 5580 <37.011, Rockwell Automation CompactLogix 5380 <34.015, Rockwell Automation CompactLogix 5380 <35.014, Rockwell Automation CompactLogix 5380 <36.013, Rockwell Automation CompactLogix 5380 <37.011, Rockwell Automation Compact GuardLogix 5380 <34.015, Rockwell Automation Compact GuardLogix 5380 <35.014, Rockwell Automation Compact GuardLogix 5380 <36.013, Rockwell Automation Compact GuardLogix 5380 <37.011, Rockwell Automation CompactLogix 5480 <34.015, Rockwell Automation CompactLogix 5480 <35.014, Rockwell Automation CompactLogix 5480 <36.013, Rockwell Automation CompactLogix 5480 <37.011
Product Status:known_affected
Remediations
Vendor fixRockwell Automation recommends users update to firmware version 34.015 and later.
Vendor fixRockwell Automation recommends users update to firmware version 35.014 and later.
Vendor fixRockwell Automation recommends users update to firmware version 36.013 and later.
Vendor fixRockwell Automation recommends users update to firmware version 37.011 and later.
MitigationCustomers using the affected software who are not able to upgrade to one of the corrected versions should use Rockwell Automation's security best practices.
Relevant CWE: CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')Metrics
CVSS Version
Base Score
Base Severity
Vector String
3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0
8.7
HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Acknowledgments
- Rockwell Automation reported this vulnerability to CISA
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
Revision History
- Initial Release Date: 2026-09-01
Date
Revision
Summary
2026-09-01
1
Initial republication of Rockwell Automation advisory